試験法対応表 USP対応表
USP対応表 液相
本対応表は信和化工株式会社よりご提供いただいたデータを基に作成されています。
| Code | Support | Commercially Available |
|---|---|---|
| G1 | Dimethylpolysiloxane oil | ULBON HR-1 Silicone OV-101 |
| G2 | Dimethylpolysiloxane gum | ULBON HR-1 Silicone OV-1 Silicone SE-30 |
| G3 | 50% Phenyl-50% methylpolysiloxane | ULBON HR-17 Silicone OV-17 |
| G4 | Diethylene glycol succinate polyester | DEGS |
| G5 | 3-Cyanopropylpolysiloxane | Silicone OV-275 |
| G6 | Trifluoropropylmethylpolysiloxane | Silicone OV-210 Silicone DC QF-1 |
| G7 | 50% 3-Cyanopropyl-50% phenylmethylsilicone | Silicone OV-235 |
| G8 | 80% Bis(3-Cyanopropyl)-20% 3-cyanopropylphenylpolysiloxane | Silicone OV-255 |
| G9 | Methylvinylpolysiloxane OV-1 | Silicone OV-1 |
| G11 | Bis(2-ethylhexyl)sebacate polyester | Octoil-S(DOS) |
| G13 | Sorbitol | Sorbitol |
| G14 | Polyethylene glycol(av.mol.wt. of 950 to 1050) | PEG-1000 |
| G15 | Polyethylene glycol(av.mol.wt. of 3000 to 3700) | PEG-4000 |
| G16 | Polyethylene glycol compound(av. mol. wt. about 15,000). A high molecular weight compound of polyethylene glycol with a diepoxide linker. Available commercially as Polyethylene Glycol Compound 20M, or as Carbowax 20M, from suppliers of chromatographic reagents. |
ULBON HR-20M PEG-20M |
| G17 | 75% Phenyl 25% methylpolysiloxane | Silicone OV-25 |
| G18 | Polyalkylene glycol | Ucon LB-550X |
| G19 | 25% Phenyl 25% Cyanopropyl 50% methylsilicone | Silicone OV-225 |
| G20 | Polyethylene glycol(av.mol.wt. of 380 to 420) | PEG-400 |
| G21 | Neopentyl glycol succinate | Neopentylglycol succinate(NGS) |
| G22 | Bis(2-ethylhexyl)phthalate | Dioctyl phthalate(DOP) |
| G23 | Polyethylene glycol adipate | Ethylene glycol adipate(EGA) |
| G24 | Diisodecyl phthalate | Diisodecyl phthalate(DIDP) |
| G25 | Polyethylene glycol compound TPA. A high molecular weight compound of a polyethylene glycol and a diepoxide that is esterified with terephtharic acid. Available commercially as Carbowax 20M-TPA from supplier of chromatographic reagents. |
PEG-20M TPA |
| G26 | 25% 2-Cyanoethyl 75% methylpolysiloxane | Silicone OV-225 |
| G27 | 5% Phenyl 95% methylpolysiloxane | ULBON HR-52 Silicone SE-52 Silicone SE-54 |
| G28 | 25% Phenyl 75% methylpolysiloxane | Silicone DC-550 |
| G29 | 3,3’-Thiodipropionitrile | 3,3’-Thiodipropionitrile(TDPN) |
| G30 | Tetraethylene glycol dimethyl ether | Tetraethylene glycol dimethyl ether(BMEE) |
| G31 | Nonylphenoxypoly(ethyleneoxy)ethanol(av. Ethyleneoxy chain length is 30); Nonoxynol 30. |
Igepal CO-880 |
| G32 | 20% Phenylmethyl 80% dimethylpolysilicone | Silicone OV-7 |
| G34 | Diethylene glycol succinate polyester stabilized with phosphoric acid. | DEGS+H₃PO₄ |
| G35 | A high molecular weight compound of polyethylene glycol and a diepoxide that is esterified with nitroterephthalic acid. |
FON FFAP |
| G36 | 1% Vinyl 5% phenylmethylpolysiloxane | ULBON HR-52 Silicone SE-52 Silicone SE-54 |
| G39 | Polyethylen glycol(av.mol.wt. about 1500) | PEG-1500 |
| G40 | Ethylene glycol adipate | Ethylene Glycol Adipate(EGA) |
| G41 | Phenylmethyldimethylpolysiloxane(10% Phenyl substituted) | Silicone OV-3 |
| G42 | 35% phenyl-65% dimethylpolysiloxane (percentages refer to molar substitution). |
Silicone OV-11 |
| G44 | 2% low molecular weight petroleum hydrocarbon grease and 1% solution of potassium hydroxide. |
Apiezon L |
| G45 | Divinylbebzebe-ethylene glycol dimethylacrylate | Sunpak-E Porapak N |
| G46 | 14% cyanopropylphenyl-86% methylpolysiloxane. | ULBON HR-1701 |